英格瑪特/力士樂伺服驅(qū)動器故障維修:控制器是針對伺服電機特殊使用而的,也可能專為某些產(chǎn)品而制造,選用哪種控制信形式因設(shè)計師個人規(guī)劃理念而定,或選用控制器與驅(qū)動器一體規(guī)劃,絡(luò)式遠程控制,這些不是通用伺服電機評論的規(guī)模,但工作理論及工作形式是相同的。
DDS02.2-W驅(qū)動器F262輸出處故障修理:
F262 External Short at Status Outputs
狀態(tài)輸出處的外部短路
Description:說明:Status outputs are monitored for short circuits and thermal overload.監(jiān)測狀態(tài)輸出是否存在短路和熱過載。
• If output current exceeds 350mA for about 1μs, then this is acknowledged as a short circuit and the pertinent channel is shut off.
•如果輸出電流超過350mA約1μs,則為確認為短路,并關(guān)閉相關(guān)通道。
The output remains off unti the error is cleared.
在清除錯誤之前,輸出保持關(guān)閉。
• With thermal overload, the error is set and the output(s) shut off. After
the driver has cooled off, the outputs are switched back on and so on.
•熱過載時,設(shè)置錯誤并關(guān)閉輸出驅(qū)動器已經(jīng)冷卻,輸出重新打開,等等。
The error, however, remains until it is cleared. Thermal overload can
occur if several outputs are overloaded in excess of 80 mA.然而,該錯誤將一直存在,直到清除為止。熱過載可能如果多個輸出過載超過80mA。
Cause:原因:
1. Short circuited outputs (X2/6, X2/7, X2/8, X2/9, X2/10, X2/20,X2/21, X2/22)
短路輸出(X2/6、X2/7、X2/8、X2/9、X2/10、X2/20、X2/21,X2/22)
2. One or more outputs are overloaded.
一個或多個輸出過載。
Remedy:解決措施:
For 1. Eliminate short circuit or limit switching current (< 350 mA)
對于1。消除短路或限制開關(guān)電流(<350 mA)
For 2. Drop current, depending on output, to < 80 mA.
對于2。根據(jù)輸出,將電流降至<80 mA。
友情提示:請勿自行拆卸檢查或交給非專業(yè)人士,以免越修越壞,造成不必要的經(jīng)濟損失!早一天聯(lián)系,少一天損失!上海仰光電子科技有限公司 因為專注,所以專業(yè)!
轉(zhuǎn)載請注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動器維修,伺服電機維修