力士樂DKS01.1-W050A-DL01-01-FW維修:F218 Heatsink Overtemperature Shutdown散熱器過熱停機。
Description:說明:The temperature of the DKC heatsink will be monitored. If the temperature of the heatsink is too high, the drive will power down in order to protect against damage.將監測DKC散熱器的溫度。如果散熱器溫度過高,驅動器將按順序斷電以防止損壞。
力士樂伺服放大器線路板維修:Cause:
1. Ambient temperature is too high. The specifiedoperational data is valid up to an ambient temperature of 45°C.
環境溫度過高。指定的操作數據在45°C的環境溫度下有效。
2. The DKC's heatsink is dirty.
DKC的散熱器臟了。
3. Air flow is prevented by other assembly parts or a control cabinet panel assembly.
氣流由其他組件零件或控制柜面板組件阻止。
4. Heatsink blower may be defective
散熱器鼓風機可能存在故障
Remedy:
1. Reduce the ambient temperature; for example, through cooling of the control cabinet
降低環境溫度;例如,通過冷卻控制柜
2. Remove any obstruction or dirt from the heatsink.
清除散熱器上的任何障礙物或污垢。
3. Install the device vertically and clear a large enough area for proper heatsink ventilation.
垂直安裝設備,并清理足夠大的區域,以便進行適當的散熱器通風。
4. Exchange drive.
交換驅動器。