黃浦倍福伺服驅(qū)動(dòng)器維修:F73F, Feedback "general": Feedback id has been incorrectly parametrized反饋“常規(guī)”:反饋id參數(shù)設(shè)置錯(cuò)誤。
The internal ID parametrized in the feedback system does not correspond to the ID entered in the IDN "P-0-0150" or "P-0-0180".反饋系統(tǒng)中參數(shù)化的內(nèi)部ID與IDN“P-0-0150”或“P-0-0180”中輸入的ID不一致。
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
診斷代碼(十六進(jìn)制)診斷代碼(Dez)
F73F 63295
Class Type
類別類型
Error Parameter error
參數(shù)錯(cuò)誤
Standard Reaction Reset
標(biāo)準(zhǔn)反應(yīng)復(fù)位
The power stage is already switched off Execute Reset-Command (S-0-0099).
電源級已關(guān)閉執(zhí)行復(fù)位命令(S-0-0099)。
Possible Causes Solutions
可能的原因解決方案
You have selected an incorrect feedback system. Compare the selected feedback system with the actually existing one.
您選擇的反饋系統(tǒng)不正確。將選定的反饋系統(tǒng)與實(shí)際存在的反饋系統(tǒng)進(jìn)行比較。
The feedback database was incorrectly parametrized. Call our support dept. and replace the feedback database.
反饋數(shù)據(jù)庫的參數(shù)設(shè)置不正確。致電我們的支持部門并更換反饋數(shù)據(jù)庫。
During the motor replacement a motor with different feedback was connected.
在更換電機(jī)期間,連接了一個(gè)具有不同反饋的電機(jī)。
Please correct the feedback-parameterization.
請更正反饋參數(shù)化。
Further Information AX5000_IDN-Description: "P-0-0150-->Parameter channel-->Identifier" or "P-0-0180-->Parameter channel-->Identifier。進(jìn)一步信息AX5000_IDN-說明:“P-0-0150-->參數(shù)通道-->標(biāo)識(shí)符”或“P-0-0180-->參數(shù)通道->標(biāo)識(shí)符。